Journal of Sports Science and Medicine
Journal of Sports Science and Medicine
ISSN: 1303 - 2968   
Ios-APP Journal of Sports Science and Medicine
Androit-APP Journal of Sports Science and Medicine
Views
7452
Download
1013
from September 2014
 
©Journal of Sports Science and Medicine (2008) 07, 132 - 138

Research article
Aerobic Fitness Level Typical of Elite Athletes is not Associated With Even Faster VO Kinetics During Cycling Exercise
Tiago R. Figueira, Fabrizio Caputo, Carlos E.P. Machado, Benedito S. Denadai   
Author Information
Human Performance Laboratory, Rio Claro S.P., Brasil

Benedito S. Denadai
✉ Human Performance Laboratory, UNESP. Av. 24 A, 1515, Bela Vista, Rio Claro, SP, CEP - 13506-900, Brasil.
Email: bdenadai@rc.unesp.br
Publish Date
Received: 14-03-2007
Accepted: 07-01-2008
Published (online): 01-03-2008
 
ABSTRACT

The aim of this study was to address the question if the VO2 kinetics is further improved as the aerobic training status increases from trained to elite level athletes. Maximal oxygen uptake (VO2max), work-rate associated to VO2max (IVO2max) and VO2 kinetics of moderate (Mod) and maximal exercise (Max) were determined in fifty- five subjects. Then, they were assigned into three groups: low (LF), intermediate (IF) and high (HF) aerobic fitness level. In average, the VO2max of LF, IF and HF groups were, respectively, 36.0 ± 3.1, 51.1 ± 4.5 and 68.1 ± 3.9 ml·kg·min-1 (p ≤ 0.05 among each other). VO2 kinetics mean response time of both exercise intensities were significantly faster (p ≤ 0.05) in HF (Mod, 27.5 ± 5.5 s; Max, 32.6 ± 8.3 s) and IF (Mod, 25.0 ± 3.1 s; Max, 42.6 ± 10.4 s) when compared to LF (Mod, 35.7 ± 7.9 s; Max: 57.8 ± 17.8 s). We can conclude that VO2 kinetics is improved as the fitness level is increased from low to intermediate but not further improved as the aerobic fitness level increases from intermediate to high.

Key words: Oxidative metabolism, VO kinetics, aerobic training


           Key Points
  • Currently, it is reasonable to believe that the rate-limiting step of VO kinetics depends on exercise intensity.
  • The well known physiological adaptations induced by endurance training are likely the most extreme means to overcome rate-limiting steps determining VO kinetics across exercise intensities.
  • However, exercise adaptation leading individuals to the high-end of aerobic fitness level range (VOmax > 65 ml.kg.min-1) is not able to further improve VO kinetics during both, moderate and maximal intensity exercise.

INTRODUCTION

Pulmonary gas- exchange kinetics has been used to gain insight into oxidative energy release within active muscle during transitions to a higher metabolic rate (i.e., rest-exercise transition). The speed at which oxidative energy metabolism increases towards the new energy requirement imposed by exercise is the main determinant of oxygen deficit, and hence the cell reliance on non-oxidative ATP turnover (Özyener et al., 2003). From an homeostatic view, the VO2 kinetics analysis is particularly insightful in pathological conditions where exercise tolerance may be compromised by limited aerobic energy turnover due to impaired O2 transport and/ utilization with consequent higher internal milieu disturbance (conditions such as aging and cardio-respiratory diseases are associated with slow VO2 kinetics response) (for a review, see Xu and Rhodes, 1999). On the other hand, health adults may present wide inter-individual differences in VO2 kinetics speed (expressed as time constant or mean response time - MRT), but apparently non-related to sub-maximal exercise tolerance. Rather than focusing on the consequences of either quite slow or fast VO2 kinetics values on exercise tolerance, VO2 kinetics analysis in several pathological and physiological conditions altering O2 transport and metabolism has been thought to be valuable, since such conditions may provide insights into the regulation of aerobic energy release in response to an abrupt challenge of cell energy homeostasis (i.e., transition to a higher metabolic rate) (Grassi et al., 1998; Grassi, 2001; MacDonald et al., 1997).

In the search for the culprit of such initial incompetence of aerobic energy release in providing ATP resynthesis at a rate that lately is achieved during square-wave exercise, many studies have attempted to manipulate the rate-limiting steps involved in O2 transport and utilization (Grassi et al., 1998; MacDonald et al., 1997). From these several animal and humans experimental models, mainly two hypotheses regarding the rate- liming step (O2 delivery vs. O2 utilization) have been addressed (Grassi, 2001; Hughson et al., 2001). Currently, it is reasonable to believe that the rate-limiting step of VO2 kinetics depends on exercise intensity.

The leading findings suggest that the VO2 kinetics of moderate-intensity exercise (below lactate threshold) is limited peripherally by O2 utilization and that at higher exercise intensities, the O2 delivery begins to exert limitation on VO2 kinetics (Grassi, 2001; Hughson et al., 2001). The well known physiological adaptations induced by endurance exercise are likely the most extreme means to overcome rate-limiting steps determining VO2 kinetics across exercise intensities. However, its impact on VO2 kinetics speeding may vary as the operating rate- limiting step does across exercise intensities (Krustrup et al., 2004). Unfortunately, this interaction between aerobic fitness level and the rate-limiting steps of VO2 kinetics over the wide range of exercise intensities has never been addressed, since the direct assessment of required variables face methodological issues such as invasiveness.

Far from directly answering the question above, there are some studies showing the association between aerobic fitness level and VO2 kinetics response, which seem worth in providing details for future mechanistic studies. These studies have described that the VO2 kinetics is improved as the aerobic fitness level increases (i.e. moving from sedentary/active to trained aerobic status) up to a point where VO2 kinetics is not further improved by increasing aerobic fitness (Phillips et al., 1995; Carter et al., 2000). Such response could suggest a possible upper limit for VO2 kinetics to improve. However, these studies have evaluated this association in individuals whose aerobic fitness level was well bellow the values possible to achieve with years of competitive endurance training (i.e. VO2max > 65 ml·kg·min-1). In this scenario it is still unknown if aerobic fitness level typical of elite athletes are associated with even faster VO2 kinetics than that presented by trained individuals. Based on previous works (Carter et al., 2000; Phillips et al., 1995), we hypothesize that VO2 kinetics stop improving as aerobic fitness level still does so. Along in this issue, the exercise intensity at which VO2 kinetics is analyzed may show different influences of aerobic fitness level on VO2 kinetics, since the intensity specific rate-limiting step of VO2 kinetics could undergo differential adaptation to endurance training (Krustrup et al., 2004).

The aim of the present study is to address the question if the VO2 kinetics is further improved as the aerobic training status (aerobic fitness level) increases from trained to elite level athletes. Additionally we evaluated this response in two exercise intensities (moderate- intensity exercise and maximal-intensity exercise) where the likely rate-limiting step is different from each other.

METHODS

Subjects

Among sixty-seven subjects tested (sedentary subjects, recreational and national level cyclists volunteered for this study), fifty-five individuals matching the criterions of one of our groups were selected to participate in this study. These subjects were assigned into six groups (three aerobic fitness levels X two exercise intensities) based on their aerobic fitness level (VO2max) and exercise intensity performed (maximal intensity - Max or moderate intensity - Mod). The different levels of aerobic fitness were named as follow: Low aerobic fitness level (LF), intermediate aerobic fitness level (IF) and high aerobic fitness level (HF). The number of individuals in each of the 6 groups (N) is described in Table 1. All subjects gave informed consent and the protocol was approved by the university’s ethics committee. The subjects were asked to avoid exercise training during the last 2 days before each test and to report to the laboratory at least 3 h after the last meal. Table 1 shows the subject’s characteristics of each group.

Experimental design

The subjects performed 1) an incremental test to determine the maximal oxygen uptake (VO2max) and the intensity associated with the achievement of VO2max (iVO2max); 2) constant work-rate cycling exercises to exhaustion at the intensity corresponding to 50% (moderate-intensity exercise - Mod) or 100% (maximal-intensity exercise - Max) of VO2max to determine the time constant of oxygen uptake response (MRT - mean response time). Thereafter, those individuals matching the VO2max range values of one of the three aerobic fitness level groups (LF - below 40 ml·kg·min-1; IF - between 43 and 60 ml·kg·min-1; HF - above 63 ml·kg·min-1) were selected. All tests were performed at the same time of day in a climate-controlled (21-22°C) laboratory. Subjects performed only one test on any given day and the tests were at least 48 h apart from each other but completed within the period of 2 weeks.

Procedures

The tests were conducted on a mechanically braked cycle ergometer (Monark 828E, Stockholm, Sweden) with the pedal frequency maintained constant at 70 rpm (Ciclocomputer Cateye, Japan). Throughout the tests, gas-exchange variables were measured breath-by-breath using a portable gas analyzer system (Cosmed K4b2, Rome, Italy). These analyzers have previously been validated over a wide range of exercise intensities (Mclaughlin et al., 2001). Before each test, the O2 and CO2 analysis systems were calibrated using ambient air and a gas of known O2 and CO2 concentration according to the manufacturer’s instructions, while the K4b2 turbine flowmeter was calibrated using a 3-l syringe (Cosmed K4b2, Rome, Italy). Earlobe capillary blood samples (25 l) were collected into a glass tube and were analyzed for lactate concentration using an automated analyzer (YSI 2300, Ohio, USA).

Subjects performed incremental exercise to volitional exhaustion to determine VO2max and iVO2max at the cycle ergometer. The test started at 70 W with increases in power output of 35 W every 3 min. Each subject was encouraged to give a maximum effort and the blood was sampled at the point of exhaustion. Breath-by-breath VO2 was smoothed using a five-step average filter, and then reduced to 15 s stationary averages for incremental test (Data Management Software, Cosmed, Rome, Italy) to reduce the noise. The VO2max was defined as the highest 15 s VO2 value reached during the incremental test. All subjects fulfilled at least two of the following three criteria for VO2max: 1) respiratory exchange ratio (R) greater than 1.1, 2) a blood lactate concentration greater than 8 mM, and 3) peak HR at least equal to 90% of the age-predicted maximal (Taylor et al., 1955). The iVO2max was defined as the minimal power output at which VO2max occurred (Billat and Koralsztein, 1996).

The subjects subsequently performed a constant work rate test (at 50% VO2max - Mod exercise or at 100% VO2max - Max exercise) to determine VO2 kinetics parameters. The subjects were instructed to perform the required intensity until the exhaustion (cadence < 65 rpm for 10 consecutive sec or voluntary exhaustion) at Max exercise or for 6 min at Mod exercise. At the start of cycling exercise, the subjects cycled against zero resistance, until a pedal cadence of 70 rpm was reached, at that point, the pre-selected work rate was imposed and timing began. Oxygen consumption data from constant work-rate tests were filtered for aberrant values (values not included in the interval of average ± 4 SD were excluded).

VO kinetics curve fitting

The VO2 kinetics during constant work-rate was modeled with a mono-exponential function by an iterative non-linear regression process from the Microcal Origin 6.0 (Northampton, MA, USA) using the following equation (Lamarra et al., 1987):

Where: VO2(t) represents oxygen uptake at time (t), VO2b is the baseline value of VO2 at rest, A is the amplitude of the increase in VO2 above the baseline value and 𝜏 is the mean response time - MRT (defined as the time required to attain 63% of A). In order to increase the confidence of estimated parameters of the equation (Lamarra et al., 1987), VO2b and A were constrained at the fitting window, respectively, as the mean value at the minute before constant work-rate exercise onset and as the difference between VO2b and the end exercise VO2 value.

Statistical analysis

Data are presented as mean + SD. The effects of aerobic fitness on VO2 kinetics were tested using one-way ANOVA, with Tukey’s post-hoc tests where appropriate. ANOVA two-way was applied to compare all other variables across groups (exercise intensity vs. fitness level). Pearson product moment coefficients were used to assess the significance of relationships between VO2 kinetics and VO2max. Statistical significance was set at p ≤ 0.05.

RESULTS

Table 2 contains the indexes of aerobic fitness level obtained from progressive intensity exercise (VO2max, iVO2max relative to body mass and absolute iVO2max) and the mean response time (MRT) that describes VO2 kinetics during Mod and Max exercises. All indexes of aerobic fitness were significantly different (p ≤ 0.05) between the three levels of aerobic fitness. MRT of the IF and HF groups were significantly faster than MRT of LF group, however, there was no difference between IF and HF groups for this variable (p > 0.05).

Figure 1 and 2">2 show the coefficient of correlation between MRT of, respectively, Mod (r = -0.51; p ≤ 0.05) and Max (r = - 0.63; p ≤ 0.05) exercises and VO2max. Although these coefficients were statistically significant, VO2max explains little of MRT variability at both exercise intensities (Mod, R2 = 26%; Max, R2 = 40%).

Figure 3 and 4">4 show representative VO2 data and its curve fitting of each fitness levels, respectively, at moderate and maximal exercise. The individual MRT and VO2max values of these subjects, whose data are shown, are placed on each figure panel.

DISCUSSION

To our knowledge, this is the first study evaluating the effects of aerobic fitness level on VO2 kinetics of subjects in the high-end aerobic power range (VO2max). The faster MRT along with the increase in aerobic fitness level from low to intermediate is in agreement with several reports describing such adaptation in the low-end range of aerobic fitness level (Fukuoka et al., 2002; Phillips et al., 1995; Yoshida et al., 1992). Our main results showing unchanged MRT of Mod and Max exercise as the fitness level increases from intermediate to high are somehow in line with previous short-term longitudinal data obtained from less fit subjects (Carter et al., 2000; Phillips et al,, 1995). Our current findings add to previous data by describing that exercise adaptation leading individuals to the high-end of aerobic fitness level range (VO2max near of above 65 ml·kg·min-1) is not able to further improve VO2 kinetics during both, Mod and Max intensity exercise.

The subjects included in this study were assigned to one of the three groups based on aerobic fitness level (VO2max). Regarding our purpose, the composition of the high fit group is especially critical, since it must represent the high-end of aerobic fitness level. The indexes often used to describe aerobic fitness and exercise performance (VO2max and iVO2max) (Table 2) seem to match the level typical of elite athletes (Caputo and Denadai, 2004; Jeukendrup et al., 2000).

From a time course stand-point, improvements in sub-maximal VO2 kinetics of low fit individuals seem to occur very early (within a week) after exercise training program onset, even anticipating changes in other indexes of aerobic fitness such as VO2max and lactate threshold (Phillips et al., 1995). Although this time course response for maximal exercise VO2 kinetics is still unknown, it seems that as the exercise intensity increases (intensity of exercise test), the effects of aerobic training on these parameters are more likely to occur (Carter et al., 2000; Krustrup et al., 2004). Collectively, these studies cited above show a good frame of the initial response of VO2 kinetics, where aerobic fitness level and exercise intensity seem to play a role in determining VO2 kinetics changes in response to exercise training.

Within the limitation of our cross-sectional experimental design, the VO2 kinetics of maximal exercise seems to follow the same pattern of that of sub-maximal response across the three levels of aerobic fitness studied. This similar pattern between these two exercise intensities is not obvious, since VO2 kinetics during high-intensity exercise has been described to present early improvements in response to training interventions along with no concomitant changes in moderate exercise VO2 kinetics (Krustrup et al., 2004). Such disparity has been understood as a phenomenon mainly related to the difference in exercise intensity, since a reduced reliance on non-oxidative energy source may improve cell homeostasis and exercise tolerance during, particularly, high-intensity exercise (Jones et al., 2003). Our data suggest that above a certain level of aerobic fitness, this disparity between exercise intensities may no longer exist.

Phillips et al., 1995 have demonstrated that low fit adult subjects have their VO2 kinetics improved by exercise training. Along with this result, middle age subjects also present similar improvements in VO2 kinetics early after training program onset (Fukuoka et al., 2002). Interestingly, Carter et al., 2000 studying active college students (VO2max ~55 ml·kg·min-1) did not find any improvement in moderate exercise VO2 kinetics after 6 weeks of exercise training, although other indexes of aerobic fitness were improved (lactate threshold and VO2max). It seems that these findings rise two questions: Does VO2 kinetics only improve initially while aerobic fitness is rather low? And, will longer and severe training regime further improve VO2 kinetics?

Addressing the later question, our assessment of elite-level athletes seems to provide evidence that VO2 kinetics stop improving above a given level of aerobic fitness during both, maximal and moderate exercise. This result is in accordance with previous time course study of VO2 kinetics response to exercise training and the similarity of MRT reported here (Table 2) and by other studies involving highly fit subjects (Koppo et al., 2004; Kilding et al., 2007). Hence, this value of MRT may represent the fastest speed that VO2 kinetics can be.

Some studies have reported significant relationship between VO2max and VO2 kinetics speed (Powers et al., 1985; Gurd et al., 2005). In spite of significant correlation coefficients between VO2max and MRT at both exercise intensities when all the groups are joined together (Figure 1 and 2">2), their R2 are low and the difference in VO2max along with no associated difference in MRT between the intermediate and high aerobic fitness groups (Table 2), suggest a loose association between these variables. The significant correlations are probable due to the heterogeneity and the inclusion of low fit subjects whose VO2 kinetics seems still sensitive to changes in aerobic fitness level.

CONCLUSION

In conclusion, we have demonstrated that VO2 kinetics is improved when the fitness level is increased from low to intermediate but not further improved as the aerobic fitness level increases from intermediate to a high level typical of elite athletes. In addition, such response seems to be independent of exercise intensity (moderate vs. maximal).

ACKNOWLEDGEMENTS

We thank to Fundação de Amparo à Pesquisa do Estado de São Paulo - FAPESP and Fundação para o Desenvolvimento da UNESP -FUNDUNESP for financial support.

AUTHOR BIOGRAPHY

Journal of Sports Science and Medicine Tiago R. Figueira
Employment: Member of Human Performance Laboratory, UNESP- Rio Claro, São Paulo, Brazil.
Degree: MSc
Research interests: Exercise physiology, training.
E-mail: figueirat@yahoo.com.br
 

Journal of Sports Science and Medicine Fabrizio Caputo
Employment: Member of Human Performance Laboratory, UNESP- Rio Claro, São Paulo, Brazil.
Degree: PhD
Research interests: Exercise physiology, training.
E-mail: fabriziocaputo@hotmail.com
 

Journal of Sports Science and Medicine Carlos E.P. Machado
Employment: Member of Human Performance Laboratory, UNESP- Rio Claro, São Paulo, Brazil.
Degree: MSc
Research interests: Exercise physiology, training.
E-mail: cadu@bresportes.com
 

Journal of Sports Science and Medicine Benedito S. Denadai
Employment: Full Professor, Department of Physical Education, São Paulo State University, SP, Brazil.
Degree: PhD
Research interests: Exercise physiology and training.
E-mail: bdenadai@rc.unesp.br
 
 
REFERENCES
Journal of Sports Science and Medicine Özyener F., Rossiter H.B., Ward S.A., Whipp B.J. (2003) Negative accumulated oxygen deficit during heavy and very heavy intensity cycle ergometry in humans. European Journal of Applied Physiology 90, 185-190.
Journal of Sports Science and Medicine Billat V., Koralsztein J.P. (1996) Significance of the velocity at vVO2max and time to exhaustion at this velocity. Sports Medicine 22, 90-108.
Journal of Sports Science and Medicine Caputo F., Denadai B.S. (2004) Effects of aerobic endurance training status and specificity on oxygen uptake kinetics during maximal exercise. European Journal of Applied Physiology 93, 87-95.
Journal of Sports Science and Medicine Carter H., Jones A.M., Barstow T.J., Burnley M., Williams C., Doust J.H. (2000) Effect of endurance training on oxygen uptake kinetics during treadmill running. Journal of Applied Physiology 89, 1744-1752.
Journal of Sports Science and Medicine Fukuoka Y., Grassi B., Conti M., Guiducci D., Sutti M., Marconi C., Cerretelli P. (2002) Early effects of exercise training on VO2 on- and off-kinetics in 50-year-old subjects. Pflugers Archives 443, 690-697.
Journal of Sports Science and Medicine Grassi B. (2001) Regulation of oxygen consumption at exercise onset: is it really controversial?. Exercise Sports Science Review 3, 134-138.
Journal of Sports Science and Medicine Grassi B., Gladen L.B., Stary C.M, Wagner P.D., Hogan MC. (1998) Peripheral O2 diffusion does not affect VO2 on-kinetics in isolated in situ canine muscle. Journal of Applied Physiology 85, 1404-1412.
Journal of Sports Science and Medicine Gurd B.J., Scheuermann B.W., Paterson D.H., Kowalchuk J.M. (2005) Prior heavy-intensity exercise speeds VO2 kinetics during moderate-intensity exercise in young adults. Journal of Applied Physiology 98, 1371-1378.
Journal of Sports Science and Medicine Hughson R.L., Tschakovsky M.E., Houston M.E. (2001) Regulation of oxygen consumption at the onset of exercise. Exercise Sports ScienceReview 29, 129-1233.
Journal of Sports Science and Medicine Jeukendrup A.E., Craig N.P., Hawley J.A. (2000) The bioenergetics of world class cycling. Journal of Science Medicine in Sport 3, 414-433.
Journal of Sports Science and Medicine Jones A.M., Wilkerson D.P., Burnley M., Koppo K. (2003) Prior heavy exercise enhances performance during subsequent perimaximal exercise. Medicine and Science in Sports Exercise 35, 2085-2092.
Journal of Sports Science and Medicine Kilding A.E., Fysh M., Winter E.M. (2007) Relationships between pulmonary oxygen uptake kinetics and other measures of aerobic fitness in middle- and long-distance runners. European Journal of Applied Physiology 100, 105-114.
Journal of Sports Science and Medicine Koppo K., Wilkerson D.P., Bouchaert J., Wilmshurst S., Campbell I.T., Jones A.M. (2004) Influence of DCA on pulmonary VO2 kinetics during moderate-intensity cycle exercise. Medicine and Science in Sports Exercise 36, 1159-1164.
Journal of Sports Science and Medicine Krustrup P., Hellsten Y., Bangsbo J. (2004) Intense interval training enhances human skeletal muscle oxygen uptake in the initial phase of dynamic exercise at high but not at low intensities. Journal of Physiology 559, 335-345.
Journal of Sports Science and Medicine Lamarra N., Whipp B.J., Ward S.A., Wasserman K. (1987) Effect of interbreath fluctuations on characterizing exercise gas exchange kinetics. Journal of Applied Physiology 62, 2003-2012.
Journal of Sports Science and Medicine MacDonald M., Pedersen P.K., Hugson R.L. (1997) Acceleration of VO2 kinetics in heavy submaximal exercise by hyperoxia and prior high-intensity exercise. Journal of Applied Physiology 83, 1318-1325.
Journal of Sports Science and Medicine Mclaughlin J.E., King G.A., Howley E.T., Bassett D.R., Ainsworth B.F. (2001) Validation of the Cosmed K4b2 portable metabolic system. International Journal of Sports Medicine 31, 280-284.
Journal of Sports Science and Medicine Phillips S.M., Green H.J., Macdonald M.J., Hughson R.L. (1995) Progressive effect of endurance training on VO2 kinetics at the onset of submaximal exercise. Journal of Applied Physiology 79, 1914-1920.
Journal of Sports Science and Medicine Powers S.K., Dodd S., Beadle R.E. (1985) Oxygen uptake kinetics in trained athletes differing in VO2max. European Journal of Applied Physiology and Occupational Physiology 54, 306-308.
Journal of Sports Science and Medicine Taylor H.L., Buskirk E.R., Henschel A. (1955) Maximal oxygen intake as an objective measure of cardiorespiratory performance. J Appl Physiol 8, 73-80.
Journal of Sports Science and Medicine Xu F., Rhodes E.C. (1999) Oxygen uptake kinetics during exercise. Sports Medicine 27, 313-27.
Journal of Sports Science and Medicine Yoshida T., Udo M., Ohmori T., Matsumoto Y., Uramoto T., Yamamoto K. (1992) Day-to-day changes in oxygen uptake kinetics at the onset of exercise during strenuous endurance training. European Journal of Applied Physiology and Occupational Physiology 64, 78-83.
 
 
 
Home Issues About Authors
Contact Current Editorial board Authors instructions
Email alerts In Press Mission For Reviewers
Archive Scope
Supplements Statistics
Most Read Articles
  Most Cited Articles
 
  
 
JSSM | Copyright 2001-2024 | All rights reserved. | LEGAL NOTICES | Publisher

It is forbidden the total or partial reproduction of this web site and the published materials, the treatment of its database, any kind of transition and for any means, either electronic, mechanic or other methods, without the previous written permission of the JSSM.

This work is licensed under a Creative Commons License Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.